Beamshield™ Plus Loadings & Toppings

Beamshield™ Plus is the most flexible insulated infill system for suspended floors available. Partition walls for Domestic dwellings up to 5kN/lin metre* can be placed parallel and perpendicular to the span of the beam and point loads up to 4.0 kN* anywhere on the floor, even on the cantilevered edge.

All loadings have been full scale tested by a UKAS independent laboratory to Ultimate limit state and beyond to ensure that Architects can specify Beamshield™ Plus with complete confidence. Permissible load bearing for  underfloor insulation is dependent upon the chosen concrete strength and reinforcement. The use of micro fibre reinforced concrete is restricted to non NHBC sites only.

* Refer to tables for required concrete topping specification

Permissible Loadings

Domestic and Communal Area Loadings Table
For Concrete Toppings With Macro Polymer Fibres Or A142 Mesh
Characteristic loads for single family dwellings Characteristic loads for communal areas in flats
Imposed Uniformaly distributed load (UDL) (kN/m2) 1.5 3.0
Imposed concentrated load (kN) 2.0 4.0
Line load parallel & perpendicular to the beam (UDL) (kN/m2) 3.0 5.0
Allowance for moveable partition 1.0 1.0

Contact our Technical helpline
on 0845 769 7452 for more information.

Domestic and Communal Area Loadings Table
For Concrete Toppings With Micro Polymer Fibres
Characteristic loads for single family dwellings Characteristic loads for communal areas in flats
Imposed Uniformaly distributed load (UDL) (kN/m2) 1.5 2.5 *1
Imposed concentrated load (kN) 2.0 2.0
Line load parallel & perpendicular to the beam (UDL) (kN/m2) *2 *3 3.0 -
Line load perpendicular to the beam (UDL) (kN/m2) 3.0 -
Allowance for moveable partition 1.0 -
  1. The total imposed characteristic value of the uniformly distributed load and moveable partitions in communal areas in flats will not exceed 2.5 kN/m-2
  2. Line loads heavier than 1 kN must be supported by the foundation or directly beneath a beam.
  3. Line loads of 3 kN parallel to the beam must be no greater than 25% of the total span of the beam
Commercial Loadings Table For Concrete Toppings With Steel Mesh
Characteristic loads
Imposed Uniformaly distributed load (UDL) (kN/m2) 5.0
Imposed concentrated load (kN) 4.5
Line load parallel and perpendicular to the beam (UDL) (kN/m2) 5.0
Allowance for moveable partition 1.0
  • Imposed concentrated loads must not be combined with uniformally distributed loads or other variable actions
  • Imposed concentrated load for residential buildings is assumed to be applied over a square plate area of not less than 50mm x 50mm
  • Moveable and line load partitions must not be combined

Structural Concrete Toppings

Specification Type Reinforcement
Thickness
75mm
Grade Specifications
C25/30
Aggregate Size
10mm
Standard / Self levelling concrete - Macro Fibre - Durus S400 at a dosage of 45mm length x 0.9mm diameter (tensile strength 465 MPA (Modulus of Elasticity 3350 MPa) Class 11 in accordance with BS EN 14889-2:2006)
Thickness
75mm
Grade Specifications
C25/30
Aggregate Size
10mm
Standard / Self levelling concrete - One layer of A142 steel mesh to BS 4483:2005 with a characteristic yield strength of 500 N-mm-2 Nominal cover to mesh must be 35mm
Thickness
60mm
Grade Specifications
C28/30
Aggregate Size
10mm
Standard / Self levelling concrete - One layer of A142 steel mesh to BS 4483:2005 with a characteristic yield strength of 500 N-mm-2 Nominal cover to the reinforcement must be 27mm
Thickness
60mm
Grade Specifications
C28/30
Aggregate Size
10mm
Standard / Self levelling concrete - 0.75 KG-M-3 of Fibrin PC12 polypropelene fibres to BS EN 14889-2:2006 (polymer fibre class 1)
  • Note that self levelling/compacting concrete must be in accordance with BS EN 206:2013. Slump Flow classes should be SF2, SF3 or SF4. (Consistency classes, including slump flow classes, are given in BS EN 8500-1:2015 and European guidelines for self compacting concrete May 2005).
  • Note that the slump class for standard concrete should be Class S3 with a sand content greater than 47.5% and aggregate must comply with BS EN 12620:2002
  • Note that the minimum residual Flexural strength of the macro-polymer fibre concrete topping is 1.6 MPa at 05mm CMOD and 1.73 MPa at 3.5mm CMOD
  • Note that macro-polymer fibre content for each load of concrete should be measured in accordance with BS EN 14488-7:2007
  • Note that micro fibre reinforced concrete is not accepted on NHBC sites.